25/25-M5 UP

GRP support polyester 1 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 1
Breaking strength in kN: 1.5
Height in mm: 25
AC test voltage in kV: 10
Compressive force in kN: 20
Tensile force in kN: 3
Torque in Nm: 15
Fitting: M5x7
Width across flats in mm: 25
To the statements

25/25-M6 UP

GRP support polyester 1 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 1
Breaking strength in kN: 1.5
Height in mm: 25
AC test voltage in kV: 10
Compressive force in kN: 35
Tensile force in kN: 5
Torque in Nm: 15
Fitting: M6x8
Width across flats in mm: 25
To the statements

30/30-M6 UP

GRP support polyester 1 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 1
Breaking strength in kN: 2.5
Height in mm: 30
AC test voltage in kV: 15
Compressive force in kN: 45
Tensile force in kN: 6
Torque in Nm: 20
Fitting: M6x8
Width across flats in mm: 30
To the statements

30/30-M8 UP

GRP support polyester 1 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 1
Breaking strength in kN: 3
Height in mm: 30
AC test voltage in kV: 15
Compressive force in kN: 60
Tensile force in kN: 12
Torque in Nm: 40
Fitting: M8x9
Width across flats in mm: 30
To the statements

35/30-M6 UP

GRP support polyester 1 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 1
Breaking strength in kN: 2
Height in mm: 35
AC test voltage in kV: 15
Compressive force in kN: 45
Tensile force in kN: 6
Torque in Nm: 20
Fitting: M6x8
Width across flats in mm: 30
To the statements

35/30-M8 UP

GRP support polyester 1 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 1
Breaking strength in kN: 3.5
Height in mm: 35
AC test voltage in kV: 15
Compressive force in kN: 60
Tensile force in kN: 12
Torque in Nm: 40
Fitting: M8x9
Width across flats in mm: 30
To the statements

35/30-M10 UP

GRP support polyester 1 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 1
Breaking strength in kN: 4
Height in mm: 35
AC test voltage in kV: 15
Compressive force in kN: 75
Tensile force in kN: 16
Torque in Nm: 50
Fitting: M10x9
Width across flats in mm: 30
To the statements

35/40-M8 UP

GRP support polyester 1 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 1
Breaking strength in kN: 4
Height in mm: 35
AC test voltage in kV: 15
Compressive force in kN: 70
Tensile force in kN: 14
Torque in Nm: 40
Fitting: M8x9
Width across flats in mm: 40
To the statements

35/40-M10 UP

GRP support polyester 1 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 1
Breaking strength in kN: 4.5
Height in mm: 35
AC test voltage in kV: 15
Compressive force in kN: 80
Tensile force in kN: 16
Torque in Nm: 50
Fitting: M10x14
Width across flats in mm: 40
To the statements

40/30-M6 UP

GRP support polyester 2 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 2
Breaking strength in kN: 1.5
Height in mm: 40
AC test voltage in kV: 20
Compressive force in kN: 45
Tensile force in kN: 6
Torque in Nm: 20
Fitting: M6x8
Width across flats in mm: 30
To the statements

40/30-M8UP

GRP support polyester 2 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 2
Breaking strength in kN: 3
Height in mm: 40
AC test voltage in kV: 20
Compressive force in kN: 60
Tensile force in kN: 12
Torque in Nm: 40
Fitting: M8x9
Width across flats in mm: 30
To the statements

40/40-M8 UP

GRP support polyester 2 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 2
Breaking strength in kN: 5
Height in mm: 40
AC test voltage in kV: 20
Compressive force in kN: 90
Tensile force in kN: 14
Torque in Nm: 50
Fitting: M8x9
Width across flats in mm: 40
To the statements