Cable supports

Guides and supports

For guiding and supporting electrical lines and cables.

Line carrier LUKA GmbH

Cable supports

Cable carriers are mechanical support structures used in various industrial and commercial installations to guide and support electrical wires and cables. They provide organisation, protection and systematic arrangement of cables, which enables efficient maintenance and expansion of the electrical system. Cable trays can be made of various materials such as metal or plastic and are adapted to the specific environmental conditions and load requirements of the respective application.

Filtering the line carrier

FS24-12-M16

Cast resin outdoor support 24kV

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 280
Diameter in mm: 170
Bending strength in kN: 12
Creepage distance in mm: 849
Temperature range in °C: -40/+90 °C
AC withstand voltage in kV dry: 117
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 193
Foot fitting: M16x35
Head fitting: M16x35
Permissible operating voltage in kV: 24 kV
To the statements

FS36-8-M16+M20

Cast resin outdoor support 36kV

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 360
Diameter in mm: 170
Bending strength in kN: 8
Creepage distance in mm: 849
Temperature range in °C: -40/+90 °C
AC withstand voltage in kV dry: 135
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 230
Foot fitting: M20x40
Head fitting: M16x33
Permissible operating voltage in kV: 24 kV
To the statements

FS6-6-M10

Cast resin outdoor support 6kV

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 60
Diameter in mm: 60
Bending strength in kN: 6
Creepage distance in mm: 85
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 60
Foot fitting: M10x16
Head fitting: M10x16
Permissible operating voltage in kV: 6 kV
To the statements

FS6-7.5-M12

Cast resin outdoor support 6kV

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 60
Diameter in mm: 60
Bending strength in kN: 7.5
Creepage distance in mm: 85
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 60
Foot fitting: M12x18
Head fitting: M12x18
Permissible operating voltage in kV: 6 kV
To the statements

FS6-10-M16

Cast resin outdoor support 6kV

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 60
Diameter in mm: 60
Bending strength in kN: 10
Creepage distance in mm: 85
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 60
Foot fitting: M16x20
Head fitting: M16x20
Permissible operating voltage in kV: 6 kV
To the statements

FS24-12-M16+M20

Cast resin outdoor support 24kV

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 280
Diameter in mm: 170
Bending strength in kN: 12
Creepage distance in mm: 849
Temperature range in °C: -40/+90 °C
AC withstand voltage in kV dry: 117
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 193
Foot fitting: M20x34
Head fitting: M16x33
Permissible operating voltage in kV: 24 kV
To the statements

FS24-7-hanging

24kV hanging cast resin outdoor support

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 280
Diameter in mm: 135
Bending strength in kN: 7
Creepage distance in mm: 823
Temperature range in °C: -40/+90 °C
AC withstand voltage in kV dry: 50
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 125
Foot fitting: M16x42
Head fitting: M16x42
Permissible operating voltage in kV: 24 kV
To the statements

FS45-4-M16+M20

Cast resin outdoor support 45kV

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 500
Diameter in mm: 170
Bending strength in kN: 4
Creepage distance in mm: 1547
Temperature range in °C: -40/+90 °C
AC withstand voltage in kV dry: 95
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 250
Foot fitting: M20x34
Head fitting: M16x33
Permissible operating voltage in kV: 45 kV
To the statements

FS12-11 hanging

12kV hanging cast resin outdoor support

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 210
Diameter in mm: 135
Bending strength in kN: 11
Creepage distance in mm: 514
Temperature range in °C: -40/+90 °C
AC withstand voltage in kV dry: 50
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 125
Foot fitting: M16x42
Head fitting: M16x42
Permissible operating voltage in kV: 12 kV
To the statements

A12N-2 M16/M16 Cyclo

Cast resin outdoor support 12 kV

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 130
Diameter in mm: 60
Bending strength in kN: 5
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 75
Foot fitting: M16x33
Head fitting: M16x33
Permissible operating voltage in kV: 12 kV
To the statements

40/40-M10 GH Cyclo

Cast resin outdoor support 2kV

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 40
Diameter in mm: 45
Bending strength in kN: 6
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Open-air facility
Foot fitting: M10x12
Head fitting: M10x12
To the statements

A12N-1 M10/M16 Cyclo

Cast resin outdoor support 12kV

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 130
Diameter in mm: 60
Bending strength in kN: 5
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 75
Foot fitting: M16x33
Head fitting: M16x20
To the statements

FS36-8 hanging

36kV hanging cast resin outdoor support

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 360
Diameter in mm: 135
Bending strength in kN: 8
Creepage distance in mm: 981
Temperature range in °C: -40/+90 °C
AC withstand voltage in kV dry: 70
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 170
Foot fitting: M16x42
Head fitting: M16x42
Permissible operating voltage in kV: 36 kV
To the statements

FS36-5-M10+M16

Cast resin outdoor support 36kV

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 360
Diameter in mm: 135
Bending strength in kN: 5
Creepage distance in mm: 980
Temperature range in °C: -40/+90 °C
AC withstand voltage in kV dry: 70
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 170
Foot fitting: M16x33
Head fitting: M10x20
Permissible operating voltage in kV: 36 kV
To the statements

FS24-5-M16+M16

Cast resin outdoor support 12kV

Support insulator made of cycloaliphatic epoxy casting resin for outdoor systems

Total length in mm: 0
Height in mm: 210
Diameter in mm: 135
Bending strength in kN: 5
Creepage distance in mm: 514
Temperature range in °C: -40/+90 °C
AC withstand voltage in kV dry: 50
Indoor/outdoor system: Open-air facility
Rated AC voltage in kV: 125
Foot fitting: M16x33
Head fitting: M16x33
Permissible operating voltage in kV: 24 kV
To the statements

GKD 12/55

Cast resin screw feedthrough

Screwable feedthrough for indoor systems

Total length in mm: 0
Creepage distance in mm: 120
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Indoor facility
Permissible operating voltage in kV: 45632 kV
To the statements

GKD 12/75

Cast resin screw feedthrough

Screwable feedthrough for indoor systems

Total length in mm: 0
Creepage distance in mm: 120
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Indoor facility
Permissible operating voltage in kV: 45632 kV
To the statements

GKD 12/95

Cast resin screw feedthrough

Screwable feedthrough for indoor systems

Total length in mm: 0
Creepage distance in mm: 120
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Indoor facility
Permissible operating voltage in kV: 45632 kV
To the statements

GKD 24-36/55

Cast resin screw feedthrough

Screwable feedthrough for indoor systems

Total length in mm: 0
Creepage distance in mm: 230
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Indoor facility
Permissible operating voltage in kV: 24/36 kV
To the statements

GKD 24-36/75

Cast resin screw feedthrough

Screwable feedthrough for indoor systems

Total length in mm: 0
Creepage distance in mm: 230
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Indoor facility
Permissible operating voltage in kV: 24/36 kV
To the statements

GKD 24-36/115

Cast resin screw feedthrough

Screwable feedthrough for indoor systems

Total length in mm: 0
Creepage distance in mm: 230
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Indoor facility
Permissible operating voltage in kV: 24/36 kV
To the statements

GKD 24-36/145

Cast resin screw feedthrough

Screwable feedthrough for indoor systems

Total length in mm: 0
Creepage distance in mm: 230
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Indoor facility
Permissible operating voltage in kV: 24/36 kV
To the statements

GDD 12/95

Cast resin through-hole feedthrough

Through-hole feedthrough for indoor systems

Total length in mm: 0
Creepage distance in mm: 140
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Indoor facility
Rated AC voltage in kV: 28
Permissible operating voltage in kV: 12 kV
To the statements

GDD 24/75

Cast resin through-hole feedthrough

Through-hole feedthrough for indoor systems

Total length in mm: 0
Creepage distance in mm: 250
Temperature range in °C: -40/+90 °C
Indoor/outdoor system: Indoor facility
Rated AC voltage in kV: 50
Permissible operating voltage in kV: 24 kV
To the statements