Cable supports

Guides and supports

For guiding and supporting electrical lines and cables.

Line carrier LUKA GmbH

Cable supports

Cable carriers are mechanical support structures used in various industrial and commercial installations to guide and support electrical wires and cables. They provide organisation, protection and systematic arrangement of cables, which enables efficient maintenance and expansion of the electrical system. Cable trays can be made of various materials such as metal or plastic and are adapted to the specific environmental conditions and load requirements of the respective application.

Filtering the line carrier

40/40-M10 UP

GRP support polyester 2 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 2
Breaking strength in kN: 8
Height in mm: 40
AC test voltage in kV: 20
Compressive force in kN: 90
Tensile force in kN: 20
Torque in Nm: 90
Fitting: M10x14
Width across flats in mm: 40
To the statements

40/40-M12 UP

GRP support polyester 2 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 2
Breaking strength in kN: 9
Height in mm: 40
AC test voltage in kV: 20
Compressive force in kN: 120
Tensile force in kN: 22
Torque in Nm: 100
Fitting: M12x14
Width across flats in mm: 40
To the statements

40/50-M10 UP

GRP support polyester 2 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 2
Breaking strength in kN: 12.5
Height in mm: 40
AC test voltage in kV: 20
Compressive force in kN: 140
Tensile force in kN: 23
Torque in Nm: 120
Fitting: M10x14
Width across flats in mm: 50
To the statements

40/50-M12 UP

GRP support polyester 2 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 2
Breaking strength in kN: 12.5
Height in mm: 40
AC test voltage in kV: 20
Compressive force in kN: 180
Tensile force in kN: 28
Torque in Nm: 200
Fitting: M12x14
Width across flats in mm: 50
To the statements

50/40-M8UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 5
Height in mm: 50
AC test voltage in kV: 25
Compressive force in kN: 90
Tensile force in kN: 14
Torque in Nm: 50
Fitting: M8x9
Width across flats in mm: 40
To the statements

50/40-M10 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 5
Height in mm: 50
AC test voltage in kV: 25
Compressive force in kN: 100
Tensile force in kN: 20
Torque in Nm: 90
Fitting: M10x14
Width across flats in mm: 40
To the statements

50/40-M12 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 6
Height in mm: 50
AC test voltage in kV: 25
Compressive force in kN: 120
Tensile force in kN: 22
Torque in Nm: 100
Fitting: M12x14
Width across flats in mm: 40
To the statements

50/50-M10 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 10
Height in mm: 50
AC test voltage in kV: 25
Compressive force in kN: 140
Tensile force in kN: 23
Torque in Nm: 120
Fitting: M10x14
Width across flats in mm: 50
To the statements

50/50-M12 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 10
Height in mm: 50
AC test voltage in kV: 25
Compressive force in kN: 200
Tensile force in kN: 28
Torque in Nm: 200
Fitting: M12x14
Width across flats in mm: 50
To the statements

60/40-M8 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 4
Height in mm: 60
AC test voltage in kV: 25
Compressive force in kN: 90
Tensile force in kN: 14
Torque in Nm: 50
Fitting: M8x9
Width across flats in mm: 40
To the statements

60/40-M10 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 6
Height in mm: 60
AC test voltage in kV: 25
Compressive force in kN: 100
Tensile force in kN: 20
Torque in Nm: 90
Fitting: M10x14
Width across flats in mm: 40
To the statements

60/40-M12 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 6
Height in mm: 60
AC test voltage in kV: 25
Compressive force in kN: 100
Tensile force in kN: 20
Torque in Nm: 120
Fitting: M12x14
Width across flats in mm: 40
To the statements

60/50-M10 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 9
Height in mm: 60
AC test voltage in kV: 25
Compressive force in kN: 140
Tensile force in kN: 23
Torque in Nm: 120
Fitting: M10x14
Width across flats in mm: 50
To the statements

60/50-M12 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 11
Height in mm: 60
AC test voltage in kV: 25
Compressive force in kN: 180
Tensile force in kN: 28
Torque in Nm: 200
Fitting: M12x14
Width across flats in mm: 50
To the statements

60/60-M12 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 12
Height in mm: 60
AC test voltage in kV: 25
Compressive force in kN: 220
Tensile force in kN: 28
Torque in Nm: 200
Fitting: M12x14
Width across flats in mm: 60
To the statements

60/60-M16 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 15
Height in mm: 60
AC test voltage in kV: 25
Compressive force in kN: 240
Tensile force in kN: 32
Torque in Nm: 300
Fitting: M16x20
Width across flats in mm: 60
To the statements

60/60-M20 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 16
Height in mm: 60
AC test voltage in kV: 25
Compressive force in kN: 240
Tensile force in kN: 37
Torque in Nm: 300
Fitting: M20x20
Width across flats in mm: 60
To the statements

80/60-M10 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 11
Height in mm: 80
AC test voltage in kV: 25
Compressive force in kN: 220
Tensile force in kN: 32
Torque in Nm: 200
Fitting: M10x14
Width across flats in mm: 60
To the statements

80/60-M12 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 15
Height in mm: 80
AC test voltage in kV: 25
Compressive force in kN: 240
Tensile force in kN: 37
Torque in Nm: 300
Fitting: M12x14
Width across flats in mm: 60
To the statements

80/60-M16 UP

GRP support polyester 3 kV

Low voltage support insulator made of glass fiber reinforced polyester resin

Total length in mm: 0
AC operating voltage in kV: 3
Breaking strength in kN: 15
Height in mm: 80
AC test voltage in kV: 25
Compressive force in kN: 240
Tensile force in kN: 37
Torque in Nm: 300
Fitting: M16x20
Width across flats in mm: 60
To the statements